771: The object must have its connection set before it can be used.
Summary
When attempting to access a repository object, you may receive the following error:
The object must have its connection set before it can be used. [771]
Causes
- The amount of client connections may have reached it limit.
- The Laserfiche server registration may be corrupted.
- The Laserfiche server may not support connections from the client bases on its version.
Resolutions
- Increase the maximum amount of allowed connections by editing the HKCU\Software\Laserfiche\LFSO\Version\MaxConnections registry value, where Version is the Laserfiche version number. After editing the value, restart the client.
- Open the Administration Console on the Laserfiche server, unregister the repository, then register it.
- Ensure compatibility between client and server. For example, connections from Laserfiche 10.4 clients are not supported when using Laserfiche Server 11.